BATTANT PVC ISO-CLASSIC & THERMA (3 series)

Manufacturer : Portes & Fenetres President Inc.
Certification #: 1289-005
Product/Series Name: BATTANT PVC ISO-CLASSIC & THERMA (3 series)
Operator Type: CSSV
Issue Date: 11/28/2023
Revision Date: N/A
Expiration: 10/03/2028
Report Number: TPE23011-1-C_CSSV-a-3
Specification: CSA A440.2-22
Product Simulated By: Veridis Solutions
Air Leakage Report No.: UW-00135-C1

Associated Documents

Product Number Manufacturer Product Code Emissivity (Surface #) U-Factor (Metric) SHGC Visible Transmittance (VT) Air Leakage Average (L75) Energy Rating
1289-005-0001-01 3mm, 7-8, CG70#2-arg95-PCl, iu 0.025(#2) 1.44 0.25 0.49 0.1 23
1289-005-0002-01 3mm, 7-8, CG70#2-arg95-PCl, iu, Grids < 1” 0.025(#2) 1.44 0.23 0.44 0.1 22
1289-005-0003-01 3mm, 7-8, CG70#2-arg95-PCl, iu, Grids > 1” 0.025(#2) 1.44 0.21 0.4 0.1 20
1289-005-0004-01 3mm, 7-8, CG70#2-arg95-PCl, iu, SDL >= 1” 0.025(#2) 1.44 0.21 0.4 0.1 20
1289-005-0005-01 3mm, 7-8, PCl-arg95-8071#3, iu 0.082(#3) 1.52 0.51 0.57 0.1 36
1289-005-0006-01 3mm, 7-8, PCl-arg95-8071#3, iu, Grids < 1” 0.082(#3) 1.52 0.47 0.51 0.1 34
1289-005-0007-01 3mm, 7-8, PCl-arg95-8071#3, iu, Grids > 1” 0.082(#3) 1.52 0.42 0.46 0.1 31
1289-005-0008-01 3mm, 7-8, PCl-arg95-8071#3, iu, SDL >= 1” 0.082(#3) 1.52 0.42 0.46 0.1 31
1289-005-0009-01 3mm, 1 1-4, 8071#2-arg95-PCl-arg95-8071#5, iu 0.082(#2) 0.082(#5) 0.99 0.42 0.51 0.1 42
1289-005-0010-01 3mm, 1 1-4, 8071#2-arg95-PCl-arg95-8071#5, iu, Grids < 1” 0.082(#2) 0.082(#5) 0.99 0.38 0.46 0.1 40
1289-005-0011-01 3mm, 1 1-4, 8071#2-arg95-PCl-arg95-8071#5, iu, Grids > 1” 0.082(#2) 0.082(#5) 0.99 0.35 0.41 0.1 38
1289-005-0012-01 3mm, 1 1-4, 8071#2-arg95-PCl-arg95-8071#5, iu, SDL >= 1” 0.082(#2) 0.082(#5) 0.99 0.35 0.41 0.1 38
1289-005-0013-01 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-CG70#5, iu 0.025(#2) 0.025(#5) 0.92 0.21 0.37 0.1 32
1289-005-0014-01 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-CG70#5, iu, Grids < 1” 0.025(#2) 0.025(#5) 0.92 0.19 0.34 0.1 31
1289-005-0015-01 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-CG70#5, iu, Grids > 1” 0.025(#2) 0.025(#5) 0.92 0.17 0.3 0.1 29
1289-005-0016-01 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-CG70#5, iu, SDL >= 1” 0.025(#2) 0.025(#5) 0.92 0.17 0.3 0.1 29
1289-005-0017-01 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-PCl, iu 0.025(#2) 1.15 0.23 0.45 0.1 28
1289-005-0018-01 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-PCl, iu, Grids < 1” 0.025(#2) 1.15 0.21 0.41 0.1 27
1289-005-0019-01 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-PCl, iu, Grids > 1” 0.025(#2) 1.15 0.2 0.37 0.1 26
1289-005-0020-01 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-PCl, iu, SDL >= 1” 0.025(#2) 1.15 0.2 0.37 0.1 26
1289-005-0021-01 3mm, 1 1-4, PCl-arg95-PCl-arg95-8071#5, iu 0.082(#5) 1.18 0.47 0.52 0.1 41
1289-005-0022-01 3mm, 1 1-4, PCl-arg95-PCl-arg95-8071#5, iu, Grids < 1” 0.082(#5) 1.18 0.43 0.47 0.1 39
1289-005-0023-01 3mm, 1 1-4, PCl-arg95-PCl-arg95-8071#5, iu, Grids > 1” 0.082(#5) 1.18 0.39 0.42 0.1 36
1289-005-0024-01 3mm, 1 1-4, PCl-arg95-PCl-arg95-8071#5, iu, SDL >= 1” 0.082(#5) 1.18 0.39 0.42 0.1 36
1289-005-0025-01 3mm, 7-8, CG70#2-arg95-GCl, ms 0.025(#2) 1.44 0.25 0.48 0.1 23
1289-005-0026-01 3mm, 7-8, CG70#2-arg95-GCl, ms, Grids < 1” 0.025(#2) 1.44 0.23 0.44 0.1 22
1289-005-0027-01 3mm, 7-8, CG70#2-arg95-GCl, ms, Grids > 1” 0.025(#2) 1.44 0.21 0.4 0.1 20
1289-005-0028-01 3mm, 7-8, CG70#2-arg95-GCl, ms, SDL >= 1” 0.025(#2) 1.44 0.21 0.4 0.1 20
1289-005-0029-01 3mm, 7-8, GCl-arg95-8071#3, ms 0.082(#3) 1.53 0.5 0.57 0.1 35
1289-005-0030-01 3mm, 7-8, GCl-arg95-8071#3, ms, Grids < 1” 0.082(#3) 1.53 0.46 0.51 0.1 33
1289-005-0031-01 3mm, 7-8, GCl-arg95-8071#3, ms, Grids > 1” 0.082(#3) 1.53 0.42 0.46 0.1 31
1289-005-0032-01 3mm, 7-8, GCl-arg95-8071#3, ms, SDL >= 1” 0.082(#3) 1.53 0.42 0.46 0.1 31
1289-005-0033-01 3mm, 7-8, GUCl-arg95-8071#3, ms 0.082(#3) 1.53 0.53 0.57 0.1 37
1289-005-0034-01 3mm, 7-8, GUCl-arg95-8071#3, ms, Grids < 1” 0.082(#3) 1.53 0.48 0.52 0.1 34
1289-005-0035-01 3mm, 7-8, GUCl-arg95-8071#3, ms, Grids > 1” 0.082(#3) 1.53 0.44 0.47 0.1 32
1289-005-0036-01 3mm, 7-8, GUCl-arg95-8071#3, ms, SDL >= 1” 0.082(#3) 1.53 0.44 0.47 0.1 32
1289-005-0037-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-8071#5, ms 0.082(#2) 0.082(#5) 0.97 0.42 0.5 0.1 43
1289-005-0038-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-8071#5, ms, Grids < 1” 0.082(#2) 0.082(#5) 0.97 0.38 0.46 0.1 41
1289-005-0039-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-8071#5, ms, Grids > 1” 0.082(#2) 0.082(#5) 0.97 0.34 0.41 0.1 38
1289-005-0040-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-8071#5, ms, SDL >= 1” 0.082(#2) 0.082(#5) 0.97 0.34 0.41 0.1 38
1289-005-0041-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-CG70#5, ms 0.025(#2) 0.025(#5) 0.91 0.21 0.37 0.1 32
1289-005-0042-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-CG70#5, ms, Grids < 1” 0.025(#2) 0.025(#5) 0.91 0.19 0.34 0.1 31
1289-005-0043-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-CG70#5, ms, Grids > 1” 0.025(#2) 0.025(#5) 0.91 0.17 0.3 0.1 30
1289-005-0044-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-CG70#5, ms, SDL >= 1” 0.025(#2) 0.025(#5) 0.91 0.17 0.3 0.1 30
1289-005-0045-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-GCl, ms 0.025(#2) 1.14 0.23 0.44 0.1 28
1289-005-0046-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-GCl, ms, Grids < 1” 0.025(#2) 1.14 0.21 0.4 0.1 27
1289-005-0047-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-GCl, ms, Grids > 1” 0.025(#2) 1.14 0.19 0.36 0.1 26
1289-005-0048-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-GCl, ms, SDL >= 1” 0.025(#2) 1.14 0.19 0.36 0.1 26
1289-005-0049-01 3mm, 1 1-4, GCl-arg95-GCl-arg95-8071#5, ms 0.082(#5) 1.17 0.45 0.52 0.1 40
1289-005-0050-01 3mm, 1 1-4, GCl-arg95-GCl-arg95-8071#5, ms, Grids < 1” 0.082(#5) 1.17 0.41 0.47 0.1 38
1289-005-0051-01 3mm, 1 1-4, GCl-arg95-GCl-arg95-8071#5, ms, Grids > 1” 0.082(#5) 1.17 0.38 0.42 0.1 36
1289-005-0052-01 3mm, 1 1-4, GCl-arg95-GCl-arg95-8071#5, ms, SDL >= 1” 0.082(#5) 1.17 0.38 0.42 0.1 36
1289-005-0053-01 3mm, 7-8, GCl-arg95-8071#3, sp 0.082(#3) 1.49 0.5 0.57 0.1 36
1289-005-0054-01 3mm, 7-8, GCl-arg95-8071#3, sp, Grids < 1” 0.082(#3) 1.49 0.46 0.51 0.1 34
1289-005-0055-01 3mm, 7-8, GCl-arg95-8071#3, sp, Grids > 1” 0.082(#3) 1.49 0.42 0.46 0.1 31
1289-005-0056-01 3mm, 7-8, GCl-arg95-8071#3, sp, SDL >= 1” 0.082(#3) 1.49 0.42 0.46 0.1 31
1289-005-0057-01 3mm, 7-8, GUCl-arg95-8071#3, sp 0.082(#3) 1.49 0.53 0.57 0.1 38
1289-005-0058-01 3mm, 7-8, GUCl-arg95-8071#3, sp, Grids < 1” 0.082(#3) 1.49 0.48 0.52 0.1 35
1289-005-0059-01 3mm, 7-8, GUCl-arg95-8071#3, sp, Grids > 1” 0.082(#3) 1.49 0.44 0.47 0.1 33
1289-005-0060-01 3mm, 7-8, GUCl-arg95-8071#3, sp, SDL >= 1” 0.082(#3) 1.49 0.44 0.47 0.1 33
1289-005-0061-01 3mm, 7-8, 6227#2-arg95-IS20#4, ss 0.023(#2) 0.198(#4) 1.24 0.18 0.42 0.1 23
1289-005-0062-01 3mm, 7-8, 6227#2-arg95-IS20#4, ss, Grids < 1” 0.023(#2) 0.198(#4) 1.24 0.16 0.38 0.1 22
1289-005-0063-01 3mm, 7-8, 6227#2-arg95-IS20#4, ss, Grids > 1” 0.023(#2) 0.198(#4) 1.24 0.15 0.34 0.1 21
1289-005-0064-01 3mm, 7-8, 6227#2-arg95-IS20#4, ss, SDL >= 1” 0.023(#2) 0.198(#4) 1.24 0.15 0.34 0.1 21
1289-005-0065-01 3mm, 7-8, 6227#2-arg95-GCl, ss 0.023(#2) 1.42 0.18 0.43 0.1 19
1289-005-0066-01 3mm, 7-8, 6227#2-arg95-GCl, ss, Grids < 1” 0.023(#2) 1.42 0.17 0.39 0.1 19
1289-005-0067-01 3mm, 7-8, 6227#2-arg95-GCl, ss, Grids > 1” 0.023(#2) 1.42 0.15 0.35 0.1 17
1289-005-0068-01 3mm, 7-8, 6227#2-arg95-GCl, ss, SDL >= 1” 0.023(#2) 1.42 0.15 0.35 0.1 17
1289-005-0069-01 3mm, 7-8, 8071#2-arg95-IS20#4, ss 0.082(#2) 0.198(#4) 1.31 0.46 0.55 0.1 38
1289-005-0070-01 3mm, 7-8, 8071#2-arg95-IS20#4, ss, Grids < 1” 0.082(#2) 0.198(#4) 1.31 0.42 0.5 0.1 35
1289-005-0071-01 3mm, 7-8, 8071#2-arg95-IS20#4, ss, Grids > 1” 0.082(#2) 0.198(#4) 1.31 0.38 0.45 0.1 33
1289-005-0072-01 3mm, 7-8, 8071#2-arg95-IS20#4, ss, SDL >= 1” 0.082(#2) 0.198(#4) 1.31 0.38 0.45 0.1 33
1289-005-0073-01 3mm, 7-8, CG70#2-arg95-IS20#4, ss 0.025(#2) 0.198(#4) 1.24 0.24 0.47 0.1 27
1289-005-0074-01 3mm, 7-8, CG70#2-arg95-IS20#4, ss, Grids < 1” 0.025(#2) 0.198(#4) 1.24 0.22 0.43 0.1 25
1289-005-0075-01 3mm, 7-8, CG70#2-arg95-IS20#4, ss, Grids > 1” 0.025(#2) 0.198(#4) 1.24 0.2 0.38 0.1 24
1289-005-0076-01 3mm, 7-8, CG70#2-arg95-IS20#4, ss, SDL >= 1” 0.025(#2) 0.198(#4) 1.24 0.2 0.38 0.1 24
1289-005-0077-01 3mm, 7-8, CG70#2-arg95-GCl, ss 0.025(#2) 1.42 0.25 0.48 0.1 23
1289-005-0078-01 3mm, 7-8, CG70#2-arg95-GCl, ss, Grids < 1” 0.025(#2) 1.42 0.23 0.44 0.1 22
1289-005-0079-01 3mm, 7-8, CG70#2-arg95-GCl, ss, Grids > 1” 0.025(#2) 1.42 0.21 0.4 0.1 21
1289-005-0080-01 3mm, 7-8, CG70#2-arg95-GCl, ss, SDL >= 1” 0.025(#2) 1.42 0.21 0.4 0.1 21
1289-005-0081-01 3mm, 7-8, GCl-arg95-8071#3, ss 0.082(#3) 1.5 0.5 0.57 0.1 36
1289-005-0082-01 3mm, 7-8, GCl-arg95-8071#3, ss, Grids < 1” 0.082(#3) 1.5 0.46 0.51 0.1 34
1289-005-0083-01 3mm, 7-8, GCl-arg95-8071#3, ss, Grids > 1” 0.082(#3) 1.5 0.42 0.46 0.1 31
1289-005-0084-01 3mm, 7-8, GCl-arg95-8071#3, ss, SDL >= 1” 0.082(#3) 1.5 0.42 0.46 0.1 31
1289-005-0085-01 3mm, 1 1-4, 6227#2-arg95-6227#4-arg95-IS20#6, ss 0.023(#2) 0.023(#4) 0.198(#6) 0.82 0.13 0.28 0.1 29
1289-005-0086-01 3mm, 1 1-4, 6227#2-arg95-6227#4-arg95-IS20#6, ss, Grids <
1”
0.023(#2) 0.023(#4) 0.198(#6) 0.82 0.12 0.26 0.1 29
1289-005-0087-01 3mm, 1 1-4, 6227#2-arg95-6227#4-arg95-IS20#6, ss, Grids >
1”
0.023(#2) 0.023(#4) 0.198(#6) 0.82 0.11 0.23 0.1 28
1289-005-0088-01 3mm, 1 1-4, 6227#2-arg95-6227#4-arg95-IS20#6, ss, SDL >=
1”
0.023(#2) 0.023(#4) 0.198(#6) 0.82 0.11 0.23 0.1 28
1289-005-0089-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-IS20#6, ss 0.023(#2) 0.198(#6) 1.01 0.17 0.38 0.1 28
1289-005-0090-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-IS20#6, ss, Grids < 1” 0.023(#2) 0.198(#6) 1.01 0.15 0.35 0.1 26
1289-005-0091-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-IS20#6, ss, Grids > 1” 0.023(#2) 0.198(#6) 1.01 0.14 0.31 0.1 26
1289-005-0092-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-IS20#6, ss, SDL >= 1” 0.023(#2) 0.198(#6) 1.01 0.14 0.31 0.1 26
1289-005-0093-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-6227#5, ss 0.023(#2) 0.023(#5) 0.88 0.16 0.29 0.1 30
1289-005-0094-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-6227#5, ss, Grids < 1” 0.023(#2) 0.023(#5) 0.88 0.14 0.26 0.1 29
1289-005-0095-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-6227#5, ss, Grids > 1” 0.023(#2) 0.023(#5) 0.88 0.13 0.24 0.1 28
1289-005-0096-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-6227#5, ss, SDL >= 1” 0.023(#2) 0.023(#5) 0.88 0.13 0.24 0.1 28
1289-005-0097-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-GCl, ss 0.023(#2) 1.11 0.17 0.39 0.1 25
1289-005-0098-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-GCl, ss, Grids < 1” 0.023(#2) 1.11 0.16 0.36 0.1 25
1289-005-0099-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-GCl, ss, Grids > 1” 0.023(#2) 1.11 0.14 0.32 0.1 24
1289-005-0100-01 3mm, 1 1-4, 6227#2-arg95-GCl-arg95-GCl, ss, SDL >= 1” 0.023(#2) 1.11 0.14 0.32 0.1 24
1289-005-0101-01 3mm, 1 1-4, 8071#2-arg95-8071#4-arg95-IS20#6, ss 0.082(#2) 0.082(#4) 0.198(#6) 0.88 0.39 0.49 0.1 43
1289-005-0102-01 3mm, 1 1-4, 8071#2-arg95-8071#4-arg95-IS20#6, ss, Grids <
1”
0.082(#2) 0.082(#4) 0.198(#6) 0.88 0.36 0.44 0.1 41
1289-005-0103-01 3mm, 1 1-4, 8071#2-arg95-8071#4-arg95-IS20#6, ss, Grids >
1”
0.082(#2) 0.082(#4) 0.198(#6) 0.88 0.33 0.4 0.1 40
1289-005-0104-01 3mm, 1 1-4, 8071#2-arg95-8071#4-arg95-IS20#6, ss, SDL >=
1”
0.082(#2) 0.082(#4) 0.198(#6) 0.88 0.33 0.4 0.1 40
1289-005-0105-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-IS20#6, ss 0.082(#2) 0.198(#6) 1.05 0.42 0.5 0.1 41
1289-005-0106-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-IS20#6, ss, Grids < 1” 0.082(#2) 0.198(#6) 1.05 0.38 0.45 0.1 39
1289-005-0107-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-IS20#6, ss, Grids > 1” 0.082(#2) 0.198(#6) 1.05 0.35 0.41 0.1 37
1289-005-0108-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-IS20#6, ss, SDL >= 1” 0.082(#2) 0.198(#6) 1.05 0.35 0.41 0.1 37
1289-005-0109-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-8071#5, ss 0.082(#2) 0.082(#5) 0.94 0.42 0.5 0.1 43
1289-005-0110-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-8071#5, ss, Grids < 1” 0.082(#2) 0.082(#5) 0.94 0.38 0.46 0.1 41
1289-005-0111-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-8071#5, ss, Grids > 1” 0.082(#2) 0.082(#5) 0.94 0.34 0.41 0.1 39
1289-005-0112-01 3mm, 1 1-4, 8071#2-arg95-GCl-arg95-8071#5, ss, SDL >= 1” 0.082(#2) 0.082(#5) 0.94 0.34 0.41 0.1 39
1289-005-0113-01 3mm, 1 1-4, CG70#2-arg95-CG70#4-arg95-IS20#6, ss 0.025(#2) 0.025(#4) 0.198(#6) 0.83 0.19 0.36 0.1 33
1289-005-0114-01 3mm, 1 1-4, CG70#2-arg95-CG70#4-arg95-IS20#6, ss, Grids <
1”
0.025(#2) 0.025(#4) 0.198(#6) 0.83 0.17 0.33 0.1 31
1289-005-0115-01 3mm, 1 1-4, CG70#2-arg95-CG70#4-arg95-IS20#6, ss, Grids >
1”
0.025(#2) 0.025(#4) 0.198(#6) 0.83 0.16 0.29 0.1 31
1289-005-0116-01 3mm, 1 1-4, CG70#2-arg95-CG70#4-arg95-IS20#6, ss, SDL >=
1”
0.025(#2) 0.025(#4) 0.198(#6) 0.83 0.16 0.29 0.1 31
1289-005-0117-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-IS20#6, ss 0.025(#2) 0.198(#6) 1.01 0.23 0.43 0.1 31
1289-005-0118-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-IS20#6, ss, Grids < 1” 0.025(#2) 0.198(#6) 1.01 0.21 0.39 0.1 30
1289-005-0119-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-IS20#6, ss, Grids > 1” 0.025(#2) 0.198(#6) 1.01 0.19 0.35 0.1 29
1289-005-0120-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-IS20#6, ss, SDL >= 1” 0.025(#2) 0.198(#6) 1.01 0.19 0.35 0.1 29
1289-005-0121-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-CG70#5, ss 0.025(#2) 0.025(#5) 0.88 0.21 0.37 0.1 33
1289-005-0122-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-CG70#5, ss, Grids < 1” 0.025(#2) 0.025(#5) 0.88 0.19 0.34 0.1 32
1289-005-0123-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-CG70#5, ss, Grids > 1” 0.025(#2) 0.025(#5) 0.88 0.17 0.3 0.1 30
1289-005-0124-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-CG70#5, ss, SDL >= 1” 0.025(#2) 0.025(#5) 0.88 0.17 0.3 0.1 30
1289-005-0125-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-GCl, ss 0.025(#2) 1.11 0.23 0.44 0.1 29
1289-005-0126-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-GCl, ss, Grids < 1” 0.025(#2) 1.11 0.21 0.4 0.1 28
1289-005-0127-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-GCl, ss, Grids > 1” 0.025(#2) 1.11 0.19 0.36 0.1 26
1289-005-0128-01 3mm, 1 1-4, CG70#2-arg95-GCl-arg95-GCl, ss, SDL >= 1” 0.025(#2) 1.11 0.19 0.36 0.1 26
1289-005-0129-01 3mm, 1 1-4, GCl-arg95-GCl-arg95-8071#5, ss 0.082(#5) 1.14 0.45 0.52 0.1 41
1289-005-0130-01 3mm, 1 1-4, GCl-arg95-GCl-arg95-8071#5, ss, Grids < 1” 0.082(#5) 1.14 0.41 0.47 0.1 39
1289-005-0131-01 3mm, 1 1-4, GCl-arg95-GCl-arg95-8071#5, ss, Grids > 1” 0.082(#5) 1.14 0.38 0.42 0.1 37
1289-005-0132-01 3mm, 1 1-4, GCl-arg95-GCl-arg95-8071#5, ss, SDL >= 1” 0.082(#5) 1.14 0.38 0.42 0.1 37
1289-005-0133-01 3mm, 7-8, CG70#2-arg97-PCl, su 0.025(#2) 1.4 0.25 0.49 0.1 24
1289-005-0134-01 3mm, 7-8, CG70#2-arg97-PCl, su, Grids < 1” 0.025(#2) 1.4 0.23 0.44 0.1 22
1289-005-0135-01 3mm, 7-8, CG70#2-arg97-PCl, su, Grids > 1” 0.025(#2) 1.4 0.21 0.4 0.1 21
1289-005-0136-01 3mm, 7-8, CG70#2-arg97-PCl, su, SDL >= 1” 0.025(#2) 1.4 0.21 0.4 0.1 21
1289-005-0137-01 3mm, 7-8, PCl-arg97-8071#3, su 0.082(#3) 1.48 0.51 0.57 0.1 37
1289-005-0138-01 3mm, 7-8, PCl-arg97-8071#3, su, Grids < 1” 0.082(#3) 1.48 0.47 0.51 0.1 35
1289-005-0139-01 3mm, 7-8, PCl-arg97-8071#3, su, Grids > 1” 0.082(#3) 1.48 0.42 0.46 0.1 32
1289-005-0140-01 3mm, 7-8, PCl-arg97-8071#3, su, SDL >= 1” 0.082(#3) 1.48 0.42 0.46 0.1 32
1289-005-0141-01 3mm, 1, PTOne#2-arg95-PLUX, su 0.029(#2) 1.43 0.32 0.5 0.1 27
1289-005-0142-01 3mm, 1, PTOne#2-arg95-PLUX, su, Grids < 1” 0.029(#2) 1.43 0.29 0.45 0.1 25
1289-005-0143-01 3mm, 1, PTOne#2-arg95-PLUX, su, Grids > 1” 0.029(#2) 1.43 0.27 0.41 0.1 24
1289-005-0144-01 3mm, 1, PTOne#2-arg95-PLUX, su, SDL >= 1” 0.029(#2) 1.43 0.27 0.41 0.1 24
1289-005-0145-01 3mm, 1, PLUX-arg95-PTLUX#3, su 0.082(#3) 1.51 0.52 0.56 0.1 37
1289-005-0146-01 3mm, 1, PLUX-arg95-PTLUX#3, su, Grids < 1” 0.082(#3) 1.51 0.47 0.51 0.1 34
1289-005-0147-01 3mm, 1, PLUX-arg95-PTLUX#3, su, Grids > 1” 0.082(#3) 1.51 0.43 0.46 0.1 32
1289-005-0148-01 3mm, 1, PLUX-arg95-PTLUX#3, su, SDL >= 1” 0.082(#3) 1.51 0.43 0.46 0.1 32
1289-005-0149-01 3mm, 1 1-4, 8071#2-arg97-PCl-arg97-8071#5, su 0.082(#2) 0.082(#5) 0.97 0.42 0.51 0.1 43
1289-005-0150-01 3mm, 1 1-4, 8071#2-arg97-PCl-arg97-8071#5, su, Grids < 1” 0.082(#2) 0.082(#5) 0.97 0.38 0.46 0.1 41
1289-005-0151-01 3mm, 1 1-4, 8071#2-arg97-PCl-arg97-8071#5, su, Grids > 1” 0.082(#2) 0.082(#5) 0.97 0.35 0.41 0.1 39
1289-005-0152-01 3mm, 1 1-4, 8071#2-arg97-PCl-arg97-8071#5, su, SDL >= 1” 0.082(#2) 0.082(#5) 0.97 0.35 0.41 0.1 39
1289-005-0153-01 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-CG70#5, su 0.025(#2) 0.025(#5) 0.91 0.21 0.37 0.1 32
1289-005-0154-01 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-CG70#5, su, Grids < 1” 0.025(#2) 0.025(#5) 0.91 0.19 0.34 0.1 31
1289-005-0155-01 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-CG70#5, su, Grids > 1” 0.025(#2) 0.025(#5) 0.91 0.17 0.3 0.1 30
1289-005-0156-01 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-CG70#5, su, SDL >= 1” 0.025(#2) 0.025(#5) 0.91 0.17 0.3 0.1 30
1289-005-0157-01 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-PCl, su 0.025(#2) 1.13 0.23 0.45 0.1 28
1289-005-0158-01 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-PCl, su, Grids < 1” 0.025(#2) 1.13 0.21 0.41 0.1 27
1289-005-0159-01 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-PCl, su, Grids > 1” 0.025(#2) 1.13 0.2 0.37 0.1 27
1289-005-0160-01 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-PCl, su, SDL >= 1” 0.025(#2) 1.13 0.2 0.37 0.1 27
1289-005-0161-01 3mm, 1 1-4, PCl-arg97-PCl-arg97-8071#5, su 0.082(#5) 1.17 0.47 0.52 0.1 41
1289-005-0162-01 3mm, 1 1-4, PCl-arg97-PCl-arg97-8071#5, su, Grids < 1” 0.082(#5) 1.17 0.43 0.47 0.1 39
1289-005-0163-01 3mm, 1 1-4, PCl-arg97-PCl-arg97-8071#5, su, Grids > 1” 0.082(#5) 1.17 0.39 0.42 0.1 37
1289-005-0164-01 3mm, 1 1-4, PCl-arg97-PCl-arg97-8071#5, su, SDL >= 1” 0.082(#5) 1.17 0.39 0.42 0.1 37
1289-005-0165-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su 0.029(#2) 1.14 0.3 0.46 0.1 32
1289-005-0166-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su, Grids < 1” 0.029(#2) 1.14 0.27 0.42 0.1 30
1289-005-0167-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su, Grids > 1” 0.029(#2) 1.14 0.25 0.38 0.1 29
1289-005-0168-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su, SDL >= 1” 0.029(#2) 1.14 0.25 0.38 0.1 29
1289-005-0169-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su 0.029(#2) 0.029(#5) 0.92 0.25 0.4 0.1 34
1289-005-0170-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su, Grids <
1”
0.029(#2) 0.029(#5) 0.92 0.23 0.36 0.1 33
1289-005-0171-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su, Grids >
1”
0.029(#2) 0.029(#5) 0.92 0.21 0.33 0.1 32
1289-005-0172-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su, SDL >=
1”
0.029(#2) 0.029(#5) 0.92 0.21 0.33 0.1 32
1289-005-0173-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su 0.082(#5) 1.17 0.47 0.51 0.1 41
1289-005-0174-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su, Grids < 1” 0.082(#5) 1.17 0.43 0.46 0.1 39
1289-005-0175-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su, Grids > 1” 0.082(#5) 1.17 0.39 0.42 0.1 37
1289-005-0176-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su, SDL >= 1” 0.082(#5) 1.17 0.39 0.42 0.1 37
1289-005-0177-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su 0.082(#2) 0.082(#5) 0.98 0.42 0.49 0.1 43
1289-005-0178-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su, Grids <
1”
0.082(#2) 0.082(#5) 0.98 0.38 0.45 0.1 40
1289-005-0179-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su, Grids >
1”
0.082(#2) 0.082(#5) 0.98 0.35 0.4 0.1 39
1289-005-0180-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su, SDL >=
1”
0.082(#2) 0.082(#5) 0.98 0.35 0.4 0.1 39
1289-005-0181-01 Foam, 3mm, 7-8, CG70#2-arg95-PCl, iu 0.025(#2) 1.43 0.25 0.49 0.1 23
1289-005-0182-01 Foam, 3mm, 7-8, CG70#2-arg95-PCl, iu, Grids < 1” 0.025(#2) 1.43 0.23 0.44 0.1 22
1289-005-0183-01 Foam, 3mm, 7-8, CG70#2-arg95-PCl, iu, Grids > 1” 0.025(#2) 1.43 0.21 0.4 0.1 21
1289-005-0184-01 Foam, 3mm, 7-8, CG70#2-arg95-PCl, iu, SDL >= 1” 0.025(#2) 1.43 0.21 0.4 0.1 21
1289-005-0185-01 Foam, 3mm, 7-8, PCl-arg95-8071#3, iu 0.082(#3) 1.51 0.51 0.57 0.1 36
1289-005-0186-01 Foam, 3mm, 7-8, PCl-arg95-8071#3, iu, Grids < 1” 0.082(#3) 1.51 0.47 0.51 0.1 34
1289-005-0187-01 Foam, 3mm, 7-8, PCl-arg95-8071#3, iu, Grids > 1” 0.082(#3) 1.51 0.42 0.46 0.1 31
1289-005-0188-01 Foam, 3mm, 7-8, PCl-arg95-8071#3, iu, SDL >= 1” 0.082(#3) 1.51 0.42 0.46 0.1 31
1289-005-0189-01 Foam, 3mm, 1 1-4, 8071#2-arg95-PCl-arg95-8071#5, iu 0.082(#2) 0.082(#5) 0.98 0.42 0.51 0.1 43
1289-005-0190-01 Foam, 3mm, 1 1-4, 8071#2-arg95-PCl-arg95-8071#5, iu, Grids
< 1”
0.082(#2) 0.082(#5) 0.98 0.38 0.46 0.1 40
1289-005-0191-01 Foam, 3mm, 1 1-4, 8071#2-arg95-PCl-arg95-8071#5, iu, Grids
> 1”
0.082(#2) 0.082(#5) 0.98 0.35 0.41 0.1 39
1289-005-0192-01 Foam, 3mm, 1 1-4, 8071#2-arg95-PCl-arg95-8071#5, iu, SDL >=
1”
0.082(#2) 0.082(#5) 0.98 0.35 0.41 0.1 39
1289-005-0193-01 Foam, 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-CG70#5, iu 0.025(#2) 0.025(#5) 0.91 0.21 0.37 0.1 32
1289-005-0194-01 Foam, 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-CG70#5, iu, Grids
< 1”
0.025(#2) 0.025(#5) 0.91 0.19 0.34 0.1 31
1289-005-0195-01 Foam, 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-CG70#5, iu, Grids
> 1”
0.025(#2) 0.025(#5) 0.91 0.17 0.3 0.1 30
1289-005-0196-01 Foam, 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-CG70#5, iu, SDL >=
1”
0.025(#2) 0.025(#5) 0.91 0.17 0.3 0.1 30
1289-005-0197-01 Foam, 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-PCl, iu 0.025(#2) 1.14 0.23 0.45 0.1 28
1289-005-0198-01 Foam, 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-PCl, iu, Grids <
1”
0.025(#2) 1.14 0.21 0.41 0.1 27
1289-005-0199-01 Foam, 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-PCl, iu, Grids >
1”
0.025(#2) 1.14 0.2 0.37 0.1 26
1289-005-0200-01 Foam, 3mm, 1 1-4, CG70#2-arg95-PCl-arg95-PCl, iu, SDL >=
1”
0.025(#2) 1.14 0.2 0.37 0.1 26
1289-005-0201-01 Foam, 3mm, 1 1-4, PCl-arg95-PCl-arg95-8071#5, iu 0.082(#5) 1.17 0.47 0.52 0.1 41
1289-005-0202-01 Foam, 3mm, 1 1-4, PCl-arg95-PCl-arg95-8071#5, iu, Grids <
1”
0.082(#5) 1.17 0.43 0.47 0.1 39
1289-005-0203-01 Foam, 3mm, 1 1-4, PCl-arg95-PCl-arg95-8071#5, iu, Grids >
1”
0.082(#5) 1.17 0.39 0.42 0.1 37
1289-005-0204-01 Foam, 3mm, 1 1-4, PCl-arg95-PCl-arg95-8071#5, iu, SDL >=
1”
0.082(#5) 1.17 0.39 0.42 0.1 37
1289-005-0205-01 Foam, 3mm, 7-8, CG70#2-arg97-PCl, su 0.025(#2) 1.39 0.25 0.49 0.1 24
1289-005-0206-01 Foam, 3mm, 7-8, CG70#2-arg97-PCl, su, Grids < 1” 0.025(#2) 1.39 0.23 0.44 0.1 23
1289-005-0207-01 Foam, 3mm, 7-8, CG70#2-arg97-PCl, su, Grids > 1” 0.025(#2) 1.39 0.21 0.4 0.1 21
1289-005-0208-01 Foam, 3mm, 7-8, CG70#2-arg97-PCl, su, SDL >= 1” 0.025(#2) 1.39 0.21 0.4 0.1 21
1289-005-0209-01 Foam, 3mm, 7-8, PCl-arg97-8071#3, su 0.082(#3) 1.47 0.51 0.57 0.1 37
1289-005-0210-01 Foam, 3mm, 7-8, PCl-arg97-8071#3, su, Grids < 1” 0.082(#3) 1.47 0.47 0.51 0.1 35
1289-005-0211-01 Foam, 3mm, 7-8, PCl-arg97-8071#3, su, Grids > 1” 0.082(#3) 1.47 0.42 0.46 0.1 32
1289-005-0212-01 Foam, 3mm, 7-8, PCl-arg97-8071#3, su, SDL >= 1” 0.082(#3) 1.47 0.42 0.46 0.1 32
1289-005-0213-01 Foam, 3mm, 1 1-4, 8071#2-arg97-PCl-arg97-8071#5, su 0.082(#2) 0.082(#5) 0.96 0.42 0.51 0.1 43
1289-005-0214-01 Foam, 3mm, 1 1-4, 8071#2-arg97-PCl-arg97-8071#5, su, Grids
< 1”
0.082(#2) 0.082(#5) 0.96 0.38 0.46 0.1 41
1289-005-0215-01 Foam, 3mm, 1 1-4, 8071#2-arg97-PCl-arg97-8071#5, su, Grids
> 1”
0.082(#2) 0.082(#5) 0.96 0.35 0.41 0.1 39
1289-005-0216-01 Foam, 3mm, 1 1-4, 8071#2-arg97-PCl-arg97-8071#5, su, SDL >=
1”
0.082(#2) 0.082(#5) 0.96 0.35 0.41 0.1 39
1289-005-0217-01 Foam, 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-CG70#5, su 0.025(#2) 0.025(#5) 0.9 0.21 0.37 0.1 32
1289-005-0218-01 Foam, 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-CG70#5, su, Grids
< 1”
0.025(#2) 0.025(#5) 0.9 0.19 0.34 0.1 31
1289-005-0219-01 Foam, 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-CG70#5, su, Grids
> 1”
0.025(#2) 0.025(#5) 0.9 0.17 0.3 0.1 30
1289-005-0220-01 Foam, 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-CG70#5, su, SDL >=
1”
0.025(#2) 0.025(#5) 0.9 0.17 0.3 0.1 30
1289-005-0221-01 Foam, 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-PCl, su 0.025(#2) 1.12 0.23 0.45 0.1 29
1289-005-0222-01 Foam, 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-PCl, su, Grids <
1”
0.025(#2) 1.12 0.21 0.41 0.1 27
1289-005-0223-01 Foam, 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-PCl, su, Grids >
1”
0.025(#2) 1.12 0.2 0.37 0.1 27
1289-005-0224-01 Foam, 3mm, 1 1-4, CG70#2-arg97-PCl-arg97-PCl, su, SDL >=
1”
0.025(#2) 1.12 0.2 0.37 0.1 27
1289-005-0225-01 Foam, 3mm, 1 1-4, PCl-arg97-PCl-arg97-8071#5, su 0.082(#5) 1.16 0.47 0.52 0.1 42
1289-005-0226-01 Foam, 3mm, 1 1-4, PCl-arg97-PCl-arg97-8071#5, su, Grids <
1”
0.082(#5) 1.16 0.43 0.47 0.1 39
1289-005-0227-01 Foam, 3mm, 1 1-4, PCl-arg97-PCl-arg97-8071#5, su, Grids >
1”
0.082(#5) 1.16 0.39 0.42 0.1 37
1289-005-0228-01 Foam, 3mm, 1 1-4, PCl-arg97-PCl-arg97-8071#5, su, SDL >=
1”
0.082(#5) 1.16 0.39 0.42 0.1 37