4600 PVC (AWN)

Manufacturer : Portes et Fenetres Novoprestige, Inc.
Certification #: 2606-003
Product/Series Name: 4600 PVC (AWN)
Operator Type: PRAW
Issue Date: 09/26/2023
Revision Date: N/A
Expiration: 08/01/2028
Report Number: TPE23008-6-C_PRAW-a-23
Specification: CSA A440.2-22
Product Simulated By: Veridis Solutions
Air Leakage Report No.: AI-03661-P1

Associated Documents

Product Number Manufacturer Product Code Emissivity (Surface #) U-Factor (Metric) SHGC Visible Transmittance (VT) Air Leakage Average (L75) Energy Rating
2606-003-0001-01 3mm, 7-8, PTOne#2-arg95-PLUX, su 0.029(#2) 1.43 0.3 0.46 0.1 26
2606-003-0002-01 3mm, 7-8, PTOne#2-arg95-PLUX, su, Grids < 1” 0.029(#2) 1.43 0.27 0.42 0.1 24
2606-003-0003-01 3mm, 7-8, PTOne#2-arg95-PLUX, su, Grids >= 1” 0.029(#2) 1.43 0.24 0.37 0.1 22
2606-003-0004-01 3mm, 7-8, PTOne#2-arg95-PLUX, su, SDL < 1” 0.029(#2) 1.43 0.27 0.42 0.1 24
2606-003-0005-01 3mm, 7-8, PTOne#2-arg95-PLUX, su, SDL >= 1” 0.029(#2) 1.43 0.24 0.37 0.1 22
2606-003-0006-01 3mm, 7-8, PLUX-arg95-PTLUX#3, su 0.082(#3) 1.51 0.48 0.52 0.1 34
2606-003-0007-01 3mm, 7-8, PLUX-arg95-PTLUX#3, su, Grids < 1” 0.082(#3) 1.51 0.44 0.47 0.1 32
2606-003-0008-01 3mm, 7-8, PLUX-arg95-PTLUX#3, su, Grids >= 1” 0.082(#3) 1.51 0.39 0.42 0.1 29
2606-003-0009-01 3mm, 7-8, PLUX-arg95-PTLUX#3, su, SDL < 1” 0.082(#3) 1.51 0.44 0.47 0.1 32
2606-003-0010-01 3mm, 7-8, PLUX-arg95-PTLUX#3, su, SDL >= 1” 0.082(#3) 1.51 0.39 0.42 0.1 29
2606-003-0011-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su 0.029(#2) 1.2 0.28 0.43 0.1 30
2606-003-0012-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su, Grids < 1” 0.029(#2) 1.2 0.25 0.39 0.1 28
2606-003-0013-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su, Grids >= 1” 0.029(#2) 1.2 0.23 0.35 0.1 27
2606-003-0014-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su, SDL < 1” 0.029(#2) 1.2 0.25 0.39 0.1 28
2606-003-0015-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PLUX, su, SDL >= 1” 0.029(#2) 1.2 0.23 0.35 0.1 27
2606-003-0016-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su 0.029(#2) 0.029(#5) 0.99 0.23 0.37 0.1 31
2606-003-0017-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su, Grids <
1”
0.029(#2) 0.029(#5) 0.99 0.21 0.34 0.1 30
2606-003-0018-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su, Grids >=
1”
0.029(#2) 0.029(#5) 0.99 0.19 0.3 0.1 29
2606-003-0019-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su, SDL < 1” 0.029(#2) 0.029(#5) 0.99 0.21 0.34 0.1 30
2606-003-0020-01 3mm, 1 1-4, PTOne#2-arg95-PLUX-arg95-PTOne#5, su, SDL >=
1”
0.029(#2) 0.029(#5) 0.99 0.19 0.3 0.1 29
2606-003-0021-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su 0.082(#5) 1.23 0.43 0.47 0.1 38
2606-003-0022-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su, Grids < 1” 0.082(#5) 1.23 0.39 0.43 0.1 35
2606-003-0023-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su, Grids >= 1” 0.082(#5) 1.23 0.36 0.38 0.1 34
2606-003-0024-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su, SDL < 1” 0.082(#5) 1.23 0.39 0.43 0.1 35
2606-003-0025-01 3mm, 1 1-4, PLUX-arg95-PLUX-arg95-PTLUX#5, su, SDL >= 1” 0.082(#5) 1.23 0.36 0.38 0.1 34
2606-003-0026-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su 0.082(#2) 0.082(#5) 1.04 0.39 0.46 0.1 40
2606-003-0027-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su, Grids <
1”
0.082(#2) 0.082(#5) 1.04 0.35 0.41 0.1 37
2606-003-0028-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su, Grids >=
1”
0.082(#2) 0.082(#5) 1.04 0.32 0.37 0.1 36
2606-003-0029-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su, SDL < 1” 0.082(#2) 0.082(#5) 1.04 0.35 0.41 0.1 37
2606-003-0030-01 3mm, 1 1-4, PTLUX#2-arg95-PLUX-arg95-PTLUX#5, su, SDL >=
1”
0.082(#2) 0.082(#5) 1.04 0.32 0.37 0.1 36