Manufacturer : Custom Window Designs, Ltd.
Certification #: 2893-005
Product/Series Name: High Fixed
Operator Type: FIXD
Issue Date: 01/11/2023
Revision Date: N/A
Expiration: 11/14/2027
Report Number: CUS22111640-c
Specification: CSA A440.2-19
Product Simulated By: WSP
Air Leakage Report No.: 21-06-B0082-6N

Associated Documents

Product Number Manufacturer Product Code Emissivity (Surface #) U-Factor (Metric) SHGC Visible Transmittance (VT) Air Leakage Average (L75) Energy Rating
2893-005-0001-01 CCl-arg97-180, ss 0.068(#3) 1.50 0.52 0.60 0.0 37
2893-005-0001-02 CCl-arg97-180, ss, Grids<1″ 0.068(#3) 1.50 0.47 0.53 0.0 34
2893-005-0002-01 GCl-arg97-8071, ss 0.082(#3) 1.52 0.54 0.61 0.0 38
2893-005-0002-02 GCl-arg97-8071, ss, Grids<1″ 0.082(#3) 1.52 0.49 0.54 0.0 35
2893-005-0003-01 180-arg97-i89, ss 0.068(#2) 0.149(#4) 1.26 0.48 0.59 0.0 40
2893-005-0003-02 180-arg97-i89, ss, Grids<1″ 0.068(#2) 0.149(#4) 1.26 0.43 0.52 0.0 37
2893-005-0004-01 CCl-arg97-CCl-arg97-180, ss 0.068(#5) 1.13 0.47 0.55 0.0 42
2893-005-0004-02 CCl-arg97-CCl-arg97-180, ss, Grids<1″ 0.068(#5) 1.13 0.42 0.49 0.0 40
2893-005-0005-01 GCl-arg97-GCl-arg97-8071, ss 0.082(#5) 1.14 0.49 0.55 0.0 43
2893-005-0005-02 GCl-arg97-GCl-arg97-8071, ss, Grids<1″ 0.082(#5) 1.14 0.44 0.49 0.0 40
2893-005-0006-01 180-arg97-CCl-arg97-180, ss 0.068(#2, #5) 0.91 0.43 0.53 0.0 45
2893-005-0006-02 180-arg97-CCl-arg97-180, ss, Grids<1″ 0.068(#2, #5) 0.91 0.38 0.47 0.0 42
2893-005-0007-01 8071-arg97-GCl-arg97-8071, ss 0.082(#2, #5) 0.93 0.45 0.54 0.0 46
2893-005-0007-02 8071-arg97-GCl-arg97-8071, ss, Grids<1″ 0.082(#2, #5) 0.93 0.40 0.48 0.0 43
2893-005-0008-01 SPCl-arg90-SG400-arg90-VCl, iu 0.113(#3) 1.24 0.51 0.55 0.0 42
2893-005-0008-02 SPCl-arg90-SG400-arg90-VCl, iu, Grids<1″ 0.113(#3) 1.24 0.45 0.49 0.0 39
2893-005-0009-01 SPCl-arg90-SPCl-arg90-SG400, iu 0.113(#5) 1.20 0.52 0.56 0.0 44
2893-005-0009-02 SPCl-arg90-SPCl-arg90-SG400, iu, Grids<1″ 0.113(#5) 1.20 0.46 0.50 0.0 40
2893-005-0010-01 VCl-arg90-SB60, iu 0.035(#3) 1.49 0.37 0.55 0.0 29
2893-005-0010-02 VCl-arg90-SB60, iu, Grids<1″ 0.035(#3) 1.49 0.33 0.49 0.0 26
2893-005-0011-01 VCl-arg90-VCl-arg90-SB60, iu 0.035(#5) 1.12 0.34 0.50 0.0 35
2893-005-0011-02 VCl-arg90-VCl-arg90-SB60, iu, Grids<1″ 0.035(#5) 1.12 0.31 0.44 0.0 33
2893-005-0012-01 SB60-arg90-SB60-arg90-VCl, iu 0.035(#2, #4) 0.90 0.24 0.44 0.0 34
2893-005-0012-02 SB60-arg90-SB60-arg90-VCl, iu, Grids<1″ 0.035(#2, #4) 0.90 0.22 0.39 0.0 33