Fixed

Manufacturer : QLine Windows & Doors Inc.
Certification #: 2870-003
Product/Series Name: Fixed
Operator Type: FIXD
Issue Date: 09/15/2022
Revision Date: N/A
Expiration: 08/08/2027
Report Number: QWD22108489-c
Specification: CSA A440.2-19
Product Simulated By: WSP
Air Leakage Report No.: 21-06-B0082-6N

Associated Documents

Product Number Manufacturer Product Code Emissivity (Surface #) U-Factor (Metric) SHGC Visible Transmittance (VT) Air Leakage Average (L75) Energy Rating
2870-003-0001-01 CCI-arg97-180, ss 0.068(#3) 1.50 0.52 0.60 0.0 37
2870-003-0001-02 CCI-arg97-180, ss, Grids<1″ 0.068(#3) 1.50 0.47 0.53 0.0 34
2870-003-0002-01 GCI-arg97-8071, ss 0.082(#3) 1.52 0.54 0.61 0.0 38
2870-003-0002-02 GCI-arg97-8071, ss, Grids<1″ 0.082(#3) 1.52 0.49 0.54 0.0 35
2870-003-0003-01 180-arg97-i89, ss 0.068(#2) 0.149(#4) 1.26 0.48 0.59 0.0 40
2870-003-0003-02 180-arg97-i89, ss, Grids<1″ 0.068(#2) 0.149(#4) 1.26 0.43 0.52 0.0 37
2870-003-0004-01 CCI-arg97-CCI-arg97-180, ss 0.068(#5) 1.13 0.47 0.55 0.0 42
2870-003-0004-02 CCI-arg97-CCI-arg97-180, ss, Grids<1″ 0.068(#5) 1.13 0.42 0.49 0.0 40
2870-003-0005-01 GCI-arg97-GCI-arg97-8071, ss 0.082(#5) 1.14 0.49 0.55 0.0 43
2870-003-0005-02 GCI-arg97-GCI-arg97-8071, ss, Grids<1″ 0.082(#5) 1.14 0.44 0.49 0.0 40
2870-003-0006-01 180-arg97-CCI-arg97-180, ss 0.068(#2, #5) 0.91 0.43 0.53 0.0 45
2870-003-0006-02 180-arg97-CCI-arg97-180, ss, Grids<1″ 0.068(#2, #5) 0.91 0.38 0.47 0.0 42
2870-003-0007-01 8071-arg97-GCI-arg97-8071, ss 0.082(#2, #5) 0.93 0.45 0.54 0.0 46
2870-003-0007-02 8071-arg97-GCI-arg97-8071, ss, Grids<1″ 0.082(#2, #5) 0.93 0.40 0.48 0.0 43
2870-003-0008-01 SPCI-arg90-SG400-arg90-VCI, iu 0.113(#3) 1.24 0.51 0.55 0.0 42
2870-003-0008-02 SPCI-arg90-SG400-arg90-VCI, iu, Grids<1″ 0.113(#3) 1.24 0.45 0.49 0.0 39
2870-003-0009-01 SPCI-arg90-SPCI-arg90-SG400, iu 0.113(#5) 1.20 0.52 0.56 0.0 44
2870-003-0009-02 SPCI-arg90-SPCI-arg90-SG400, iu, Grids<1″ 0.113(#5) 1.20 0.46 0.50 0.0 40
2870-003-0010-01 VCI-arg90-SB60, iu 0.035(#3) 1.49 0.37 0.55 0.0 29
2870-003-0010-02 VCI-arg90-SB60, iu, Grids<1″ 0.035(#3) 1.49 0.33 0.49 0.0 26
2870-003-0011-01 VCI-arg90-VCI-arg90-SB60, iu 0.035(#5) 1.12 0.34 0.50 0.0 35
2870-003-0011-02 VCI-arg90-VCI-arg90-SB60, iu, Grids<1″ 0.035(#5) 1.12 0.31 0.44 0.0 33
2870-003-0012-01 SB60-arg90-SB60-arg90-VCI, iu 0.035(#2, #4) 0.90 0.24 0.44 0.0 34
2870-003-0012-02 SB60-arg90-SB60-arg90-VCI, iu, Grids<1″ 0.035(#2, #4) 0.90 0.22 0.39 0.0 33
2870-003-0013-01 SPCI-arg90-SG400, iu 0.113(#3) 1.61 0.56 0.60 0.0 37
2870-003-0013-02 SPCI-arg90-SG400, iu, Grids<1″ 0.113(#3) 1.61 0.50 0.54 0.0 34
2870-003-0014-01 GCI-arg97-8071 im, im 0.082(#3) 1.54 0.54 0.61 0.0 37
2870-003-0014-02 GCI-arg97-8071 im, im, Grids<1″ 0.082(#3) 1.54 0.49 0.54 0.0 35
2870-003-0015-01 GCI-arg97-GCI-arg97-8071 im, im 0.082(#5) 1.17 0.49 0.55 0.0 43
2870-003-0015-02 GCI-arg97-GCI-arg97-8071 im, im, Grids<1″ 0.082(#5) 1.17 0.44 0.49 0.0 40
2870-003-0016-01 8071-arg97-GCI-arg97-8071 im, im 0.082(#2, #5) 0.95 0.45 0.54 0.0 45
2870-003-0016-02 8071-arg97-GCI-arg97-8071 im, im, Grids<1″ 0.082(#2, #5) 0.95 0.40 0.48 0.0 42