Product Certification:

Manufacturer: Dalmen Windows & Doors
Certification: 769-016
Product series name: DAL-4010ECO PVC(DH)
Operator type: VSDH
Issue date: 04/08/2026
Revision date: N/A
Expiration: 06/07/2029
Report number: TPE24007-1-C_VSDH-a-6
Specification: CSA A440.2-22
Product simulated by: Veridis Solutions
Air leakage report no: AI-05309-O1
Type of certification: CSA

Associated Documents

CSA Certificates

Product Number Manufacturer Product Code Emissivity (Surface #) U-Factor (Metric) SHGC Visible Transmittance (VT) Air Leakage Average (L75) Energy Rating
769-016-0001-1 3-3, 7_8, PTLX#2-arg97-IS20#4,
ee
0.082(#2) 0.198(#4) 1.40 0.46 0.55 0.4 35
769-016-0002-1 3-3, 7_8, PTLX#2-arg97-IS20#4, ee, Grids<1" 0.082(#2) 0.198(#4) 1.40 0.41 0.48 0.4 32
769-016-0003-1 3-3, 7_8, PTLX#2-arg97-IS20#4, ee, Grids>=1" 0.082(#2) 0.198(#4) 1.40 0.36 0.43 0.4 29
769-016-0004-1 3-3, 7_8, PLX-arg97-PTLX#3, ee 0.082(#3) 1.60 0.52 0.56 0.4 34
769-016-0005-1 3-3, 7_8, PLX-arg97-PTLX#3, ee, Grids<1" 0.082(#3) 1.60 0.46 0.50 0.4 31
769-016-0006-1 3-3, 7_8, PLX-arg97-PTLX#3, ee, Grids>=1" 0.082(#3) 1.60 0.41 0.44 0.4 28
769-016-0007-1 3-3, 7_8, PLX-arg97-PTLX#3, ee, SDL<1" 0.082(#3) 1.60 0.46 0.50 0.4 31
769-016-0008-1 3-3, 7_8, PLX-arg97-PTLX#3, ee, SDL>=1" 0.082(#3) 1.60 0.41 0.44 0.4 28
769-016-0009-1 3-3-3, 1 1_8, PTLX#2-arg97-PLX-arg97-PTLX#5, ee 0.082(#2) 0.082(#5) 1.12 0.42 0.50 0.4 39
769-016-0010-1 3-3-3, 1 1_8, PTLX#2-arg97-PLX-arg97-PTLX#5, ee,
Grids<1"
0.082(#2) 0.082(#5) 1.12 0.38 0.44 0.4 37
769-016-0011-1 3-3-3, 1 1_8, PTLX#2-arg97-PLX-arg97-PTLX#5, ee,
Grids>=1"
0.082(#2) 0.082(#5) 1.12 0.34 0.39 0.4 34
769-016-0012-1 3-3-3, 1 1_8, PTLX#2-arg97-PLX-arg97-PTLX#5, ee,
SDL<1"
0.082(#2) 0.082(#5) 1.12 0.38 0.44 0.4 37
769-016-0013-1 3-3-3, 1 1_8, PTLX#2-arg97-PLX-arg97-PTLX#5, ee,
SDL>=1"
0.082(#2) 0.082(#5) 1.12 0.34 0.39 0.4 34
769-016-0014-1 3-3-3, 1 1_8, PLX-arg97-PLX-arg97-PTLX#5, ee 0.082(#5) 1.32 0.47 0.51 0.4 37
769-016-0015-1 3-3-3, 1 1_8, PLX-arg97-PLX-arg97-PTLX#5, ee, Grids<1" 0.082(#5) 1.32 0.42 0.46 0.4 35
769-016-0016-1 3-3-3, 1 1_8, PLX-arg97-PLX-arg97-PTLX#5, ee,
Grids>=1"
0.082(#5) 1.32 0.37 0.40 0.4 32
769-016-0017-1 3-3-3, 1 1_8, PLX-arg97-PLX-arg97-PTLX#5, ee, SDL<1" 0.082(#5) 1.32 0.42 0.46 0.4 35
769-016-0018-1 3-3-3, 1 1_8, PLX-arg97-PLX-arg97-PTLX#5, ee, SDL>=1" 0.082(#5) 1.32 0.37 0.40 0.4 32
769-016-0019-1 3-3-3, 1 1_8, PLX-arg97-PTLX#3-arg97-PTLX#5, ee 0.082(#3) 0.082(#5) 1.12 0.45 0.50 0.4 41
769-016-0020-1 3-3-3, 1 1_8, PLX-arg97-PTLX#3-arg97-PTLX#5, ee,
Grids<1"
0.082(#3) 0.082(#5) 1.12 0.40 0.44 0.4 38
769-016-0021-1 3-3-3, 1 1_8, PLX-arg97-PTLX#3-arg97-PTLX#5, ee,
Grids>=1"
0.082(#3) 0.082(#5) 1.12 0.36 0.39 0.4 35
769-016-0022-1 3-3-3, 1 1_8, PLX-arg97-PTLX#3-arg97-PTLX#5, ee,
SDL<1"
0.082(#3) 0.082(#5) 1.12 0.40 0.44 0.4 38
769-016-0023-1 3-3-3, 1 1_8, PLX-arg97-PTLX#3-arg97-PTLX#5, ee,
SDL>=1"
0.082(#3) 0.082(#5) 1.12 0.36 0.39 0.4 35