Product Certification:

Manufacturer: Window Seal West Inc.
Certification: 3061-003
Product series name: 248-100 Series - Single Slider
Operator type: HSOX
Issue date: 11/20/2025
Revision date: N/A
Expiration: 03/25/2031
Report number: AT-00859 A2
Specification: CSA A440.2-19
Product simulated by: UL Laboratory Canada Inc
Air leakage report no: 17-06-M0260-VE6N
Type of certification: CSA

Associated Documents

CSA Certificates

Product Number Manufacturer Product Code Emissivity (Surface #) U-Factor (Metric) SHGC Visible Transmittance (VT) Air Leakage Average (L75) Energy Rating
3061-003-0001-01 EN_7257-Arg97-ClrGIG 0.045(#2) 1.60 0.36 0.54 0.5 25
3061-003-0001-02 EN_7257-Arg97-ClrGIG_Rect_1-4×5-8 0.045(#2) 1.60 0.32 0.48 0.5 22
3061-003-0002-01 EN_SB60-Arg97-ClrGIG 0.035(#2) 1.58 0.31 0.56 0.5 22
3061-003-0002-02 EN_SB60-Arg97-ClrGIG_Rect_1-4×5-8 0.035(#2) 1.58 0.28 0.50 0.5 21
3061-003-0003-01 EN_ClrGIG-Arg97-SG400 0.113(#3) 1.71 0.54 0.60 0.5 33
3061-003-0003-02 EN_ClrGIG-Arg97-SG400_Rect_1-4×5-8 0.113(#3) 1.71 0.48 0.54 0.5 29
3061-003-0004-01 EN_7257-Arg97-ClrGIG-Arg97-ClrGIG 0.045(#2) 1.58 0.34 0.50 0.5 24
3061-003-0005-01 EN_8071-Arg97-ClrGIG-Arg97-ClrGIG 0.082(#2) 1.61 0.47 0.56 0.5 31
3061-003-0006-01 EN_SB60-Arg97-ClrGIG-Arg97-ClrGIG 0.035(#2) 1.58 0.29 0.51 0.5 21
3061-003-0007-01 EN_ClrGIG-Arg97-ClrGIG-Arg97-SG400 0.113(#5) 1.62 0.49 0.55 0.5 32
3061-003-0008-01 EN_ClrGIG-Arg95-8071 0.082(#3) 1.66 0.55 0.61 0.5 34
3061-003-0008-02 EN_ClrGIG-Arg95-8071_Rect_1-4×5-8 0.082(#3) 1.66 0.49 0.55 0.5 31
3061-003-0009-01 EN_7036-Arg95-ClrGIG 0.036(#2) 1.59 0.30 0.54 0.5 22
3061-003-0009-02 EN_7036-Arg95-ClrGIG_Rect_1-4×5-8 0.036(#2) 1.59 0.27 0.48 0.5 20
3061-003-0010-01 EN_8071-Arg95-ClrGIG-Arg95-8071 0.082(#2) 0.082(#5) 1.40 0.45 0.55 0.5 34
3061-003-0011-01 EN_8071-Arg95-8071-Arg95-IS20 0.082(#2) 0.082(#4) 0.198(#6) 1.26 0.42 0.53 0.5 36
3061-003-0012-01 EN_7036-Arg95-ClrGIG-Arg95-7036 0.036(#2) 0.036(#5) 1.35 0.26 0.42 0.5 24
3061-003-0013-01 EN_7036-Arg95-ClrGIG-Arg95-ClrGIG 0.036(#2) 1.58 0.28 0.49 0.5 21
3061-003-0014-01 EN_7036-Arg95-ClrGIG-Arg95-8071 0.036(#2) 0.082(#5) 1.37 0.27 0.48 0.5 25
3061-003-0015-01 EN_3mm-CG70#2-Arg97-ClrGIG 0.025(#2) 1.54 0.27 0.53 0.5 21
3061-003-0015-02 EN_3mm-CG70#2-Arg97-ClrGIG_Grid<1" 0.025(#2) 1.54 0.24 0.47 0.5 19
3061-003-0016-01 EN_3mm-8071#2-Arg97-ClrGIG 0.082(#2) 1.64 0.51 0.61 0.5 33
3061-003-0016-02 EN_3mm-8071#2-Arg97-ClrGIG_Grid<1" 0.082(#2) 1.64 0.46 0.55 0.5 30
3061-003-0017-01 EN_3mm-SG400#2-Arg97-ClrGIG 0.113(#2) 1.68 0.49 0.60 0.5 31
3061-003-0017-02 EN_3mm-SG400#2-Arg97-ClrGIG_Grid<1" 0.113(#2) 1.68 0.44 0.54 0.5 28